Medical Diagnostics.
Timely Results and Time-Saving Automation.

MANTECH’s analyzers take care of analysis and preparation tasks so medical laboratories can provide clients with the patient sample and water quality data they need.

Too Many Samples to Handle?

To ensure accurate diagnosis and treatment planning, medical laboratories perform tests for various applications such as hospital water, dialysis water and patient samples (e.g., blood and urine). With hundreds of samples to test daily, limited sample volumes and time-consuming testing procedures, it can be challenging to provide prompt results that clients need to protect patients’ health and safety.

Benefit From MANTECH Solutions

For an industry where timely results are crucial, MANTECH’s analyzers alleviate medical laboratories from becoming overwhelmed with samples. Not only can MANTECH’s analyzers perform analysis, but they can also prepare samples for analysis right after they are received at the laboratory, significantly saving time previously spent manually barcode scanning, bottle uncapping, sample splitting and more.

By combining analysis and task automation together into one comprehensive solution, medical laboratories can get the results they need without delay. From patient samples to water quality testing, preparation tasks and anything in between, MANTECH’s solutions can be configured to meet each laboratory’s diverse requirements.

MANTECH Solutions
Medical Diagnostics

MANTECH’s analyzers offer flexible options to automate analyses and sample preparation steps to handle large sample throughputs efficiently.

Automated Environmental Titration and Multi-Parameter (MT Series) Analyzer

Is System Downtime Slowing Your 24/7 Diagnostic Turnaround?

In a 24/7 diagnostic environment, unreliable hardware and slow turnaround times don’t just delay results, they jeopardize patient care. Whether processing dialysis samples or high-volume screenings, you must maintain high-throughput performance without compromising the accuracy your clients demand.

Maximize Uptime and Profitability Per Sample

The MT Series provides the automation and speed required to maximize your profit per sample while maintaining consistent results across wide-ranging applications. By ensuring your facility remains productive around the clock, this system delivers the high-throughput performance necessary to scale your operations.

Because near-zero downtime is critical, our Platinum-Level Support provides the premium service and uptime your facility requires. As we expand into the medical market, MANTECH is dedicated to delivering the efficiency and specialized testing needed to secure your margins.

Start with MANTECH Solutions. Automated. Accurate. Green.

Connect with our team today to optimize your workplace with MANTECH’s automated, green-method analyzers that eliminate human error and maximize lab throughput.

Contact Us

Related Resources

MANTECH solutions are applied globally every day, from field research to real-world case studies. Explore the latest developments in water and wastewater testing through news, articles and MANTECH's FAQ page.

How do the MT Series systems prevent cross-contamination between samples?

The MT series prevents cross-contamination with IntelliRinse™ techology. IntelliRinse™ is beneficial because it uses real-time measurement to provide confirmation that your probes are 100% clean, eliminating chances of cross-contamination. Active IntelliRinse™ systems allows users to set user-defined values (e.g. rinse to a specific conductivity value) or to adjust the rinse intensity based on previous sample concentrations before moving to the next sample. This is beneficial as it improves the rinsing of probes/electrodes to ensure that cross-contamination does not occur even with particularly dirty or high-strength samples. There is also the option to have the final value measured during rinsing shown in a column on the results report, for a visual confirmation directly with sample results.

What is the minimum total liquid volume that can be measured for pH, conductivity and alkalinity with the MT Systems?

When using 50mL sample tubes, the minimum total volume can be as small as 6 ml using the TitraPro4 pH electrode and the MANTECH 5mm conductivity probe. This is due to the lower immersion depth of these electrodes and precise autosampler coordinate specifications. When using 125mL sample cups, the minimum total volume can be as small as 15mL.

What is the time of analysis per parameter and for multi-parameter analysis?

The timing for analysis of different parameters depends on several different factors, like the concentration of the sample and the equipment used.

Find a Distributor. Upgrade How You Analyze.

Our global distributor network allows you to connect with a local representative. Get expert support and direct access to MANTECH solutions.

Find a Distributor

Join MANTECH
At an Upcoming Event

Connect with us at key international conferences and trade fairs to learn, and advance sustainable science together.
See Events

June

14

Monday

ACHEMA 2027

Visit MANTECH in Hall 11.1, booth G86 at ACHEMA 2027 in Frankfurt from June 14 - 18 to see our multiparameter analyzers on display.